Derating Tabelle

Derating Table

°C 12p 50p 80p
20 2.9 A 2.1 A 1.6 A
70 2.2 A 1.6 A 1.1 A
100 1.4 A 1.0 A 0.6 A

Derating-Werte in Ampère in Abhängigkeit von Umgebungstemperatur und Polzahl.
Derating values in Amp with respect to environmental temperature and selected numbers of contacts.

9018 + 9020

Mating Height 9020
H=6.75mm H=8.25mm H=9.85mm
9018 H=6.25mm 8.0 - 9.5 9.5 - 11.0 11. - 12.6
H=9.05mm 10.8 - 12.3 12.3 - 13.8 13.9 - 15.4
H=13.65mm 15.4 - 16.9 16.9 - 18.4 18.5 - 20.0

9017 + 9020

Mating Heights 9020
H=6.75mm H=8.25mm H=9.85mm
9017 8.95 - 10.45
12.55 - 14.05
10.45 - 11.95
14.05 - 15.55
12.05 - 13.55
15.65 - 17.15

9018 + 9019

Mating Heights 9018
H=6.25mm H=9.05mm H=13.65mm
9019 7.65 - 9.15
11.25 - 12.75
10.45 - 11.95
14.05 - 15.55
15.05 - 16.55
18.65 - 20.15

9017 + 9019

Für 9017 und 9019 bestehen keine Bauhöhenoptionen. Der gekennzeichnete Abstand beträgt 15.80 - 17.30mm.

There are no profile options for 9017 and 9019. The marked dimension is15.80 - 17.30mm.